BANEL CONTROL SYSTEM

In general

foto_Banel
  • Microprocessor driving and control system which, in cooperation with the power part of the switchboard, meets the requirements of CSN EN 81-1 ČSN EN 81-2 and other related standards. All I / O circuits of the LCD display and keypad are located on the control board. Keyboard and LCD displays allow access to parameters through which the control system adapts to all types of commonly used lifts.
  • The control system can be used for up to 32 stations with one-button down-collector.
  • The system board can be expanded modularly using the Cab Control Board if required.
  • Part of the motherboard is the 3x400V, 50Hz network monitoring module (permanent sequence and phase check) and the converter for the serial code for position sensing.
  • Features of the system's basic equipment cover all requirements of commonly implemented applications.
  • If necessary, we provide a customization of the system software.

Using

  • By type of lift
    • rope single-speed, rope two-speed, rope one to three-speed with frequency inverter control, hydraulic
  • Door
    • It is possible to control all combinations of automatic and manual shaft and landing doors
  • Types of control
    • simple
    • down collective
    • up and down collective
  • Group management

    Two to five elevators can be combined into one system as a whole. The cabins of such lifts may have their own or common station buttons.

    • simple - after the accepted outside selection the nearest cab arrives
    • preferred - using a "double click" you can call the cab marked as preferred (for example larger car)
    • blocking - it is possible to call any cabin, but only one (the so-called parallel / parallel driving ban), the condition for this case are separately landing calls station- for each car

Basic functions

  • preferred call to the selected station

  • driving with a driver

  • fireman ride

  • parking the cab at the selected station

  • Switch off the elevator

  • Morning program

  • lunch program

  • Temperature monitoring and evaluation in the controller

  • preopening the door

  • cooperation with the telephone module

  • cooperation with the GSM module

  • monitoring the elevator on a PC